PSAM Myers Pump: Best Practices for Spare Pump Rotation

29 January 2026

Views: 6

PSAM Myers Pump: Best Practices for Spare Pump Rotation

Reliable well water is non-negotiable. When pressure drops to a whisper and taps run dry, everything stops—laundry, showers, livestock watering, even basic cooking. In my decades of fieldwork, I’ve watched too many homeowners scramble because a single pump failure took out their entire water supply. The fix isn’t complicated: keep a properly stored, prepped spare pump, and rotate it on a maintenance schedule so it isn’t a mystery part gathering dust. With Myers Pumps—especially the Predator Plus Series—you’ve got the right hardware. Now you need the right playbook.

Meet the Oseguera family. Luis Oseguera (39), a math teacher who tutors evenings, and his partner, Dana (37), a veterinary tech, live on 6 acres near Ellensburg, Washington, with their kids Mateo (9) and Mila (6). Their 260-foot private well had been limping along on a budget 1 HP pump. That unit—a mid-range brand—lost a bearing one Saturday morning and left them hauling five-gallon jugs from their neighbor for two days. The previous installation used the wrong staging and undersized wire, which cooked the motor slowly. After we sized their system properly and installed a Myers Predator Plus Series with a dedicated spare on the shelf, they decided to rotate the spare every 24 months to ensure it’s always drop-in ready.

Why a rotation plan? It’s the difference between a same-day fix and an expensive emergency. In this list, I’ll show you how to: size the spare correctly, store it to preserve seals and bearings, standardize fittings for fast swaps, log runtime against manufacturer curves, test windings and insulation before you need it, and time your rotation to maintain warranty integrity. I’ll also cover 2-wire vs. 3-wire realities, how to handle grit with Teflon-impregnated staging, what to include in a ready-to-drop kit, and how Myers’ 3-year warranty and Pentek-driven efficiency make the spare investment worth every penny for anyone on a private well.

Let’s get into it—so your next “pump emergency” becomes just another 90-minute maintenance task.
#1. Match Your Spare to Your Duty Point – Pump Curve, TDH, and Predator Plus Staging
When the primary fails, the spare has to hit your exact duty point—no guessing. A spare Myers submersible well pump that matches your pump curve and TDH (total dynamic head) avoids undersupply, deadheading, and premature burnout.

The technical backbone is straightforward. Start with static water level, pumping level at sustained flow, vertical lift to your pressure tank tee, and friction loss through your 1-1/4" NPT drop pipe and lateral lines. Target your household flow demand—8 to 12 GPM for most—then select the Predator Plus Series model whose best efficiency point (BEP) aligns with that duty. In 4-inch wells, a 10 GPM 1 HP multi-stage unit often hits 260–320 feet with the right staging. Total head equals lift plus pressure conversion (PSI x 2.31) plus friction. When you size the spare identical to your primary, both pumps are interchangeable—no rework, no re-piping, no re-wiring.

In the Oseguera case, we specified a Myers 1 HP, 10 GPM model with about 12–14 stages, meeting 60 PSI shutoff needs and accommodating a 40/60 pressure switch setting. Their spare is staged the same, with identical cable length, so runtime draws track nearly identical amps.
Myers Pump Curve Verification
Before a swap, I cross-check the pump’s head-capacity curve at target GPM. If the duty point is sitting at or just left of BEP, efficiency is maximized and motor heat minimized. With Myers’ Pentek XE motor, that sweet spot also keeps amperage near nameplate, reducing nuisance trips.
Friction Loss and Pipe Size Reality
At 10 GPM through 1-1/4" poly or PVC, friction stays reasonable. If you move to 3/4" or 1", friction spikes and flow suffers. When in doubt, I bump pipe size up and trim pressure with a valve topside, not choking the pump down below.
Standardize Everything
Use the same check valve, pitless adapter, torque arrestor, and wire gauge on both pumps. That standardization turns your spare into a true drop-in. Luis and Dana can swap in under two hours without a single hardware store run.

Key takeaway: start with math, end with ease. Your spare must mirror your primary—model, stages, flow—so the rotation is painless.
#2. Store It So It Starts Like New – Seals, Bearings, and Moisture Control
A great spare dies in storage more often than folks admit. Proper storage keeps nitrile rubber bearings, shaft seals, and windings healthy until the day you need them.

Seal lips like to be lubricated. I coat the input ports, threads, and intake screen with a light protective film and bag the unit in vapor-corrosion-inhibitor plastic. Keep the pump upright to avoid flattening seals. Climate-controlled storage is ideal; if that’s not possible, aim for a dry, stable area around 50–70°F. Add desiccant packs near the motor endbell to discourage moisture.

The Oseguera spare sits on a shelf 12 inches off the floor, bagged with two desiccants and labeled with purchase date, motor info, and cable length. I had Luis rotate the shaft by hand—just a few degrees—every six months to prevent brinelling on the bearings.
Electrical Preservation
Moisture is the enemy of windings. Before installation, I always megger-test the motor leads to ground. A good reading (often above 100 megohms on a dry, new motor) signals ready-to-run status.
Protect the Intake Screen
The intake screen is robust on Myers, but don’t store where critters or dust can clog it. Bagging helps, and I tape the bag closed near the cable guard.
Guard the Cable Connections
Pre-fitted with the correct wire splice kit and heat-shrink sleeves, your spare should have leads prepped and bundled. Label each conductor so you’re not figuring it out in the rain at 10 p.m.

Key takeaway: your spare should come out of storage in “install mode,” not “clean, fix, and hope” mode.
#3. Rotation Intervals That Work – Runtime Balancing, Warranty Timing, and BEP Efficiency
Set a rotation schedule before your next outage sets it for you. For most homes with 200–300-foot wells, 24–36 months is the sweet spot to put the spare in service and bench the current pump for inspection.

This strategy keeps both pumps sharing the workload over their lifespans. It also ensures the spare’s seals don’t sit static for five years. Myers’ 3-year warranty provides a generous protection window; aligning your first rotation inside that period gives you confidence and documentation. Paired with the 80%+ hydraulic efficiency Myers achieves near BEP, the runtime you put on each pump is cool-running, energy-smart runtime.

For the Oseguera family, we set 30 months. At the switch, we’ll inspect the active pump’s wire splices, ohm the windings, check amp draw under load, and verify gallons per minute at the hose bib to ensure performance hasn’t drifted.
Amp Draw and Pressure Verification
Record amperage at 40 PSI and 60 PSI with a clamp meter. A rise in amps over time can point to sand wear or rising friction losses. Catch it early, save the motor.
GPM Spot Checks
A simple timed bucket test (or flow meter) at a hose bib lets you confirm you’re still hitting your duty point. If flow drops, investigate before the pump’s next rotation.
Rotation Log
Make a pump rotation log with dates, readings, and notes. This is your story when you call PSAM tech support or need warranty assistance.

Key takeaway: rotation is about sharing the load and catching drift. Myers Pumps reward that discipline with long, predictable service.
#4. Stainless Steel That Lasts – 300 Series Construction and Corrosion Resistance in Real Wells
Spare pumps often sit for years, and wells rarely live in lab conditions. That’s why 300 series stainless steel across the shell, discharge bowl, shaft, coupling, wear ring, and suction screen on Myers is a big deal. Corrosion is slow failure, and in mineral-rich or mildly acidic water, it’s relentless.

Stainless construction preserves clearances and balance, protecting the multi-stage pump stack. When you pull a pump after two or three years in service, stainless hardware unthreads without drama. That matters when you’re rotating in winter or the motor needs a seal kit. Myers’ stainless components pair with engineered composite impellers that hold their profile better under grit exposure, keeping your duty point intact longer.

For Luis and Dana, their old pump’s discharge threads were corroded enough that we had to cut the fitting. The Myers Predator Plus unit we installed, and the spare, both use stainless threaded ends—no galling, no rusted-in-place headaches.
Why Corrosion Resistance Saves Money
Stainless parts reduce hidden costs—less time wrestling fittings, fewer parts needed during swap, fewer surprises for contractors. Time in the hole is expensive. Stainless cuts it.
Material Continuity
Corrosion-resistant components across the assembly—not just the shell—protect alignment and stage spacing. That’s pump longevity in the real world.
Field-Serviceable Confidence
A stainless, threaded assembly is easier to service on-site. When the spare becomes the primary, you can refresh seals and keep the rotation going without workshop-only tools.

Key takeaway: Myers’ all-in stainless approach protects your investment and your knuckles during rotation day.
#5. Rotation Readiness Kit – Build the Drop-In System Before You Need It
A smart spare isn’t just a pump. It’s a complete, labeled kit. For a fast rotation, stage everything.

Here’s my minimum list: pump and motor, pre-measured drop pipe, new check valve, torque arrestor, pitless adapter o-rings, stainless clamps, crimp sleeves, wire splice kit with adhesive-lined heat shrink, safety rope, tape, dielectric grease, and a spare pressure switch. Add a calibrated pressure gauge and a clamp meter. Keep a laminated schematic that shows wire colors, splice locations, and exact depth settings.

We delivered the Oseguera spare kit in a dedicated tote with every fitting bagged and labeled, plus a QR code linking to the Myers install manual and PSAM’s pump curve charts.
Pre-Assembly Wins
Pre-crimping splices (without shrinking) and pre-threading the check valve reduces swap time by 30–45 minutes. Bag and tag each step so a Saturday-night swap is realistic.
Depth and Set Point Notes
Note the static water level, pumping level, and set depth inside the well cap. Print a copy for your tote. Information beats guesswork every time.
Tank and Switch Spares
A spare 40/60 switch costs little and saves a service call if the switch is the real culprit. Replace when you rotate the pump to maintain crisp cut-in/cut-out behavior.

Key takeaway: once the call is “GO,” your rotation kit turns you into a surgeon with a prepared tray—no hunting for parts.
#6. Electrical and Control Consistency – 2-Wire vs 3-Wire, Voltage, and Control Box Simplicity
Compatibility makes rotations fast. Myers gives you flexibility: 2-wire well pump simplicity or 3-wire well pump with a control box. For most residential swaps, a 2-wire, 230V setup keeps wiring straightforward, reduces points of failure, and speeds replacement.

With Pentek XE motor technology, you get high-thrust capability and thermal overload protection built in. Lightning protection helps too—spares stored safely won’t suffer the same event as the primary if a surge sneaks in. When matching the spare, confirm voltage (115V vs 230V), wire gauge, amp rating, and control box model if using 3-wire. Label those details on the pump tote.

The Oseguera system runs 230V single-phase on a 1 HP 2-wire configuration. Their spare is identical—no control box swap, no re-termination learning curve at midnight.
Wire Gauge Discipline
Undersized wire equals heat and premature motor death. Use the same gauge and length on both pumps. Reference the Myers manual for distance-based gauge charts.
Overcurrent Protection
A properly sized breaker and fused disconnect reduce nuisance trips. Keep spare fuses in the kit to avoid extended downtime.
Grounding and Insulation Testing
Before rotation, perform insulation resistance tests. A strong reading is your green light. Weak results mean you service the spare before you’re forced to install it.

Key takeaway: keep electrical variables constant. Myers’ flexible configurations make this easy and dependable.
#7. Grit Happens – Teflon-Impregnated Staging and Composite Impellers for Sand Resistance
Even in clean wells, seasonal drawdown can pull fines. Abrasive water chews up soft hardware. Myers combats this with Teflon-impregnated staging and self-lubricating impellers—an engineered composite that resists scoring and keeps profiles truer under grit exposure.

A spare that’s stored clean and rotated on schedule benefits from these materials because performance remains steady. The pump stays closer to BEP, amp draw remains stable, and you’re not replacing a half-worn unit with another half-worn unit. You’re rotating strong to strong.

Luis and Dana’s well sees a slight uptick in sand every August. On the second summer after install, we measured nearly identical GPM at their hose bib and the same amperage draw—proof that staging materials were holding their own.
Intake Screen and Cable Guard
The Myers intake screen and cable guard are designed to reduce ingestion of larger particulates and protect lines on the way down. Add a torque arrestor to prevent rubbing.
Pumping Level Strategy
If you observe persistent grit, consider raising the set depth 5–10 feet. It’s a small flow compromise that can add years to your pump life.
Flush Strategy
When rotating, flush the line into the yard to purge fines before feeding the house. A few minutes of discharge can prevent fixture clogs.

Key takeaway: materials matter. Myers’ staged defense against abrasion makes rotation cycles predictable—not a coin toss.
#8. The Case Against Cutting Corners – Myers vs. Two Common Alternatives
In spare pump planning, I see two competitors most frequently: Franklin Electric and Red Lion. Let’s get specific.

Technical performance: Myers’ 300 series stainless steel construction across critical components resists corrosion far better than mixed-metal or thermoplastic designs. The Pentek XE motor (high-thrust, efficient windings, robust thermal protection) drives high static lifts without overheating, holding 80%+ hydraulic efficiency near BEP. By contrast, thermoplastic housings used in some Red Lion lines can deform or crack under pressure cycling and thermal changes. Franklin makes solid submersibles but often pairs with proprietary control strategies and dealer-first service ecosystems that complicate DIY-friendly rotations.

Real-world differences: Spare rotations depend on field serviceability. Myers' threaded assembly simplifies on-site staging, seal checks, and reassembly. Red Lion’s thermoplastic limitations become field headaches in deep wells where pressure and temperature cycles are substantial. With Franklin, I’ve watched homeowners stuck waiting on brand-specific control box parts for days. The whole point of a spare is control and speed; dealer bottlenecks undercut that.

Value conclusion: If your household runs on a private well, downtime has real costs—lost work hours, livestock stress, hotel nights. Myers, backed by Pentair and PSAM support, protects uptime. Over 10 years, fewer replacements and lower energy add up—worth every single penny.
#9. Warranty That Works for Rotations – Myers’ 3-Year Coverage and Documentation Discipline
A spare strategy deserves warranty clarity. Myers’ 3-year warranty sets the bar and aligns beautifully with rotation cycles. When you rotate within 24–36 months, you’re verifying performance while still inside coverage. That’s powerful protection for homeowners and contractors alike.

Documentation matters. Keep your purchase receipts, serial numbers, megger test results, amp readings, set depth, and service dates. If a failure occurs, you’ll have everything PSAM and Myers service teams need to process quickly. Remember: installation errors—wrong voltage, poor splices, missing check valve—can void coverage. A standardized rotation kit and checklist avoids those mistakes.

Luis keeps a simple binder: manuals, PSAM order confirmations, and a log sheet with pre- and post-rotation metrics. It’s professional-grade, and it’s why warranty conversations go smoothly if they ever need to happen.
What’s Typically Covered
Manufacturing defects, performance failures not tied to misuse, and workmanship issues within the term. Confirm final terms with the product literature at purchase.
What’s Not Covered
Incorrect sizing, debris damage due to improper filtration, electrical miswiring. That’s where disciplined rotation practices protect you.
PSAM Advantage
We help you size correctly, stock the right model, and ship fast. Our tech line walks you through checks that support the warranty record.

Key takeaway: pair Myers’ strong warranty with organized records, and your rotation plan becomes financially bulletproof.
#10. Fast Field Service – Threaded Assembly and On-Site Repair vs. Proprietary Systems
A spare is valuable because you can install it fast. It’s even more valuable if the pump you pulled can be serviced and returned to spare duty quickly. Myers’ field serviceable design and threaded assembly make that possible—replace seals, inspect stages, and refresh components on-site or in a garage with standard tools.

Contrast this with more proprietary approaches. Some Franklin Electric setups are best handled by their dealer network, and parts availability funnels through that channel. In a rotation scenario, that dependency adds time and cost. With Myers, any qualified contractor—or an experienced homeowner—can recondition a unit and get it back on the shelf the same week.

For the Oseguera family, we scheduled a Saturday rotation and a Monday bench service. By Wednesday, their old pump was resealed, test-ran on a tank, and back in the tote.
Parts Availability
Myers parts are well supported, and PSAM stocks common seals, impellers, and hardware. That’s what keeps rotations efficient.
Tools You’ll Need
Pipe wrenches, torque wrenches, crimpers, heat gun for shrink sleeves, clamp meter, megger. No specialty fixtures beyond a good well cap puller.
Test Before You Store
Bench test after service. Confirm amperage against nameplate and listen for bearing noise. Bag and tag with test results.

Key takeaway: you own your timeline with Myers. That autonomy keeps your water flowing and your spare ready.
#11. System Sizing for Rotation Predictability – HP, GPM, and Staging That Matches Real Demand
Rotation only works when your pump isn’t straining. Oversize the motor, and you waste energy; undersize it, and you cook it. Myers offers 1/2 HP, 3/4 HP, 1 HP, 1.5 HP, and 2 HP options, with stages matched to head requirements. The goal is simple: center your duty point near BEP.

For a 4-bedroom home at 260 feet like the Oseguera’s, a 1 HP 10 GPM submersible is a common sweet spot. It supports showers, laundry, and simultaneous fixture use without running to the far right of the curve. If you irrigate or run livestock troughs, we might discuss 15 GPM units and pipe size impacts.
Pressure Tank Sizing
A properly sized pressure tank (e.g., 44–86 gallons total volume) reduces cycling. Fewer plumbingsupplyandmore.com https://www.plumbingsupplyandmore.com/convertible-shallow-or-deep-well-jet-pump-3-4-hp.html cycles equal longer motor life—critical for both your active pump and your future-spare.
Pressure Switch Calibration
Keep a crisp 40/60 or 50/70, but confirm cut-in/cut-out with a good gauge. An out-of-calibration switch can hammer the motor with rapid short cycles.
Staging and Headroom
Give yourself 10–15% headroom above your calculated head. That margin handles seasonal drawdown and filter fouling without overworking the motor.

Key takeaway: smart sizing stabilizes your rotation schedule and keeps both pumps living long, efficient lives.
#12. Full-System Thinking – Check Valves, Pitless Adapters, and Tank Tees That Simplify Rotations
Rotations are easier when the rest of the system cooperates. A top-side check valve near the tank tee, a quality pitless adapter, and clean unions allow you to isolate, test, and flush without drama. While the submersible has its own internal check, I still like a topside check for testing and to prevent backflow when you crack lines.

During the Oseguera install, we replaced a sticky pitless with a high-quality unit and added unions at the tank tee. Now, when we rotate, isolating the house and flushing the line is a five-minute step—not a soaked basement project.
Air Volume and Pre-Charge
Set the tank pre-charge 2 PSI below cut-in. During rotation-day checks, verify pre-charge with the tank empty. Pressure balance protects the motor from rapid cycling.
Drain and Flush Ports
Install a drain bib downstream of the tank tee with clear labeling. You’ll purge grit and confirm GPM without contaminating the home’s lines post-rotation.
Valve Quality
Ball valves beat old gate valves for reliability. Use full-port models to reduce flow restriction during testing.

Key takeaway: a few smart plumbing upgrades transform rotation day into a clean, controlled operation.
#13. The Budget Trap – Myers vs. Goulds and Red Lion on Materials, Efficiency, and Lifespan
Two names come up in rotation conversations: Goulds Pumps and Red Lion. Here’s how Myers stacks up when rotation discipline meets real-world water.

Technical analysis: Goulds offers robust equipment, but many models still use cast iron components that, in certain water chemistries, corrode faster than 300 series stainless steel. Red Lion’s reliance on thermoplastic in key areas introduces creep and cracking risk under repeated pressure cycles. Myers’ all-stainless wetted components, engineered composite impellers, and Pentek XE motor tuning produce measurable durability and energy gains—especially critical when you expect to rotate and re-use the same hardware for a decade or more.

Application differences: Rotation assumes you’ll pull, inspect, and re-deploy pumps. Stainless threads break free cleanly, and composite stages maintain clearances after grit exposure. Thermoplastic distortion and corroded iron threads make service harder and shorten the pump’s useful second life. Over 8–15 years (and up to 20–30 with excellent care), Myers maintains performance closer to original specs. Cheaper pumps often suffer a 3–5-year ceiling before flow or pressure falls below household needs.

Value close: If your well is your lifeline, the “cheap now, replace twice” strategy costs more—in energy, in downtime, in frustration. Myers plus PSAM support is the high-reliability route—worth every single penny.
#14. Your Spare Rotation Checklist – A 60-Minute Plan You’ll Actually Use
Spare rotation succeeds with a repeatable list. Print this and stick it in your kit.
De-energize power, lockout, and verify with a meter. Record pre-rotation pressure, amp draw, and GPM. Isolate house, open flush valve, and drain pressure. Pull well cap, secure safety rope, extract pump with a helper. Inspect drop pipe, cable ties, and torque arrestor. Swap in the spare; confirm set depth and wire connections. Heat-shrink splices using adhesive-lined sleeves; tug-test every joint. Reinstall on pitless adapter, secure rope, and tidy cable. Power up; bleed air; verify 40/60 or 50/70 switch behavior. Measure amp draw at cut-in and steady-state; log readings. Flush to clear fines; retest GPM and pressure. Tag the removed pump with notes and service it within the week.
The Oseguera team followed this process the first time with me, then felt confident enough to handle future rotations with a friend’s help.

Key takeaway: checklists turn stress into process. With Myers hardware, the process runs smooth.
#15. Beyond the Well – Spare Philosophy for Sumps, Sewage, and Grinder Stations
Rotation isn’t just for wells. If you’ve got a Myers sump pump, Myers sewage pump, or Myers grinder pump, the same logic applies: size correctly, store right, and rotate on schedule. For duplex sewage pits, I alternate lead/lag monthly via control settings. For standalone sumps in flood-prone basements, keep a boxed spare staged with the correct couplings, check valve, and union. Rotating that spare every 18–24 months ensures the elastomers don’t die in the carton.

In homes like the Oseguera’s—daylight basement, soft soils—sump reliability matters after spring thaws. A Myers sump as primary with a staged spare ensures storms don’t turn into shop-vac weekends.
Lead/Lag Controls
In duplex pits, swap the lead pump automatically. That’s built-in rotation, equalizing wear.
Backup Power
A battery or generator backup for critical sewage/grinder systems prevents ugly failures. Test monthly.
Same-Brand Synergy
Staying in the Myers family simplifies parts, service, and performance expectations across your whole property.

Key takeaway: apply the rotation mindset across pumps. You’ll sleep better when storms hit.
FAQ: Expert Answers from the Field
Q1. How do I determine the correct horsepower for my well depth and household water demand? A1. Start with your static water level, pumping water level, vertical lift to the pressure tank tee, and estimated friction loss. Convert desired pressure to head (PSI x 2.31), then add lift and friction to get TDH. Choose a Myers deep well pump whose duty point at your target GPM—typically 8–12 GPM for a household—lands near the BEP on the pump curve. For example, a 260-foot well with a 40/60 switch often pairs with a 1 HP Myers 10 GPM unit. Check amperage at 230V and ensure your wire gauge meets distance requirements. If you irrigate or run livestock, bump to 15 GPM models and confirm pipe size to control friction. Rick’s recommendation: when in doubt, call PSAM with your measurements—we’ll run the numbers and match you to the correct stages and motor.

Q2. What GPM flow rate does a typical household need and how do multi-stage impellers affect pressure? A2. Most homes do well at 8–12 GPM continuous with short bursts higher. Multi-bath homes or light irrigation may target 12–15 GPM. In a multi-stage pump, each stage adds pressure (head). Stacking stages lets a 1 HP pump deliver usable pressure at 200–300+ feet. Myers Predator Plus units are engineered to maintain head without excessive amp draw, protecting the single-phase motor and reducing heat. Ensure your pressure tank volume supports desired flow without rapid cycling—44 to 86 gallons is common. Rick’s recommendation: align your duty point just left of BEP for efficiency and motor temperature control; you’ll see steadier pressure and longer life.

Q3. How does the Myers Predator Plus Series achieve 80% hydraulic efficiency compared to competitors? A3. Several factors: tight hydraulic clearances, high-quality engineered composite impellers, and precise staging geometry reduce recirculation losses. The Pentek XE motor complements this with efficient windings and high-thrust bearings, delivering torque without excess current. Operating near BEP minimizes hydraulic losses and motor heating, translating to real energy savings—often up to 20% annually vs. less efficient units. Rick’s recommendation: size to the curve, monitor amps, and record GPM during rotation checks. Efficiency comes from design plus correct application.

Q4. Why is 300 series stainless steel superior to cast iron for submersible well pumps? A4. Submerged components face oxygen-poor, mineral-rich environments. 300 series stainless steel resists pitting and scaling that can seize threads, distort clearances, and stress shafts. Cast iron can corrode in acidic or iron-heavy water, leading to harder removals and degraded hydraulics over time. Stainless also keeps service practical—rotations require clean unthreading and reassembly. Rick’s recommendation: if your well water is mineral-rich or slightly acidic, stainless is non-negotiable for long life and sane service.

Q5. How do Teflon-impregnated self-lubricating impellers resist sand and grit damage? A5. Myers’ Teflon-impregnated staging reduces friction and adds abrasion resistance. Self-lubricating impellers maintain surface integrity when fines pass through, preventing rapid edge rounding that saps head. By holding their shape, impellers keep the pump near its intended head-capacity curve longer, stabilizing amperage draw and pressure. Rick’s recommendation: if you see seasonal fines, raise set depth slightly and flush on rotation day. Combine that with Myers staging and you’ll extend service dramatically.

Q6. What makes the Pentek XE high-thrust motor more efficient than standard well pump motors? A6. The Pentek XE motor integrates optimized windings for lower I2R losses, high-thrust bearings to handle axial loads from multi-stage stacks, and thermal overload protection to prevent heat damage. Many models include lightning protection features, reducing failure risk from surges. This engineering allows strong startup torque and stable running amps at depth—translating to cooler, longer operation. Rick’s recommendation: pair Pentek XE with accurate sizing; efficiency gains are real but depend on proper application to the pump curve.

Q7. Can I install a Myers submersible pump myself or do I need a licensed contractor? A7. Skilled DIYers can install a Myers well pump if they follow the manual, use correct drop pipe, splices, and torque arrestors, and respect electrical safety. That said, many states require licensed installers for well work. If you DIY, have a second set of hands, use the right wire splice kit with adhesive-lined heat shrink, and test insulation before energizing. Rick’s recommendation: if the well is deeper than 150–200 feet or you’re unfamiliar with pitless adapters, hire a pro. PSAM can recommend installers.

Q8. What’s the difference between 2-wire and 3-wire well pump configurations? A8. A 2-wire configuration includes the start components in the motor itself—simplifying installation and reducing points of failure. A 3-wire configuration relies on an external control box with start capacitors and relays. 2-wire is simpler for most homes and ideal for easy rotations; 3-wire can offer diagnostic benefits and is preferred in some specific service scenarios. Rick’s recommendation: for most residential wells, 2-wire at 230V keeps rotations fast and reliable while reducing part count.

Q9. How long should I expect a Myers Predator Plus pump to last with proper maintenance? A9. With correct sizing, good water quality, and healthy rotation practices, Myers submersibles commonly deliver 8–15 years, and with excellent care, 20–30 years isn’t unusual. Key practices: keep cycles reasonable with a properly sized pressure tank, maintain clean voltage, protect from lightning, and use stainless steel fittings to avoid service damage. Rick’s recommendation: rotate your spare every 24–36 months, log amp draw and GPM, and you’ll stay ahead of wear.

Q10. What maintenance tasks extend well pump lifespan and how often should they be performed? A10. Annually: check pressure tank pre-charge, inspect the pressure switch, verify cut-in/out, and record amp draw at steady flow. Every rotation (24–36 months): megger-test windings, inspect check valve function, flush lines to clear fines, and document GPM. After storms: check for nuisance trips and verify ground integrity. Rick’s recommendation: simple, consistent checks beat sporadic major repairs.

Q11. How does Myers’ 3-year warranty compare to competitors and what does it cover? A11. Myers’ 3-year warranty is industry-leading—many brands hover at 12–18 months. It covers manufacturing defects and qualified performance issues under proper installation and use. Keep receipts, serial numbers, and service logs. PSAM helps you navigate the process fast. Rick’s plumbingsupplyandmore.com https://www.plumbingsupplyandmore.com/convertible-shallow-well-jet-pumps-1-2-hp.html recommendation: align your first rotation within the warranty window to validate performance and build a solid maintenance record.

Q12. What’s the total cost of ownership over 10 years: Myers vs budget pump brands? A12. Budget brands often need replacement in 3–5 years. Factor in two replacements, service calls, and higher energy due to lower efficiency, and the “cheap” route gets expensive quickly. Myers’ 80%+ efficiency, 300 series stainless steel durability, and serviceable design extend life and cut downtime. Over a decade, you’ll likely spend less on hardware, far less on crises, and keep your household running. Rick’s recommendation: treat your well like your home’s heart—invest once, rotate smart, and protect your time.

Conclusion: Spare Pump Rotation That Actually Works

Rotating a spare isn’t glamorous. It’s simple prevention that keeps showers hot, animals watered, and dinner on schedule. With Myers Predator Plus—stainless throughout, Teflon-impregnated staging, and a Pentek XE motor—you’re starting with the right bones. Combine that with a matched spare, a clean storage protocol, a 24–36 month rotation, and a ready-to-drop kit, and your “emergency” becomes a maintenance appointment.

PSAM carries the full lineup of Myers water well pumps, plus Myers jet pump, sump, sewage, and grinder models for whole-property confidence. We ship fast, support you with pump curves and specs, and stand behind every sale with practical, field-tested guidance. For the Oseguera family, that meant two hours to swap, a binder of baseline readings, and the peace of mind that comes from being prepared.

Ready to set up your rotation plan? Call PSAM. I’ll help you size the pump, build the kit, and schedule the rotation so your well system is—finally—worth every single penny.

Share